Idrija mercury smelting plant
Arkova ulica 50
5280
Idrija, Slowenien
Architekt
Besitzer
Bewohner
Ansprechpartner
Other Information
http://www.cudhg-idrija.si/en
https://idrija.si/files/other/news/54/599691.pdf
Klimazone DFc
Höhe über dem Meer 300 m ü.d.M.
Heizgradtage 250
Ensembleschutz:
Ja
Stufe der Unterschutzstellung:
UNESCO World Heritage List, cultural monument of national importance
Letzte Sanierung:
2017
Gebäudebelegung:
Unoccupied
Gebäudetyp:
industrial plant
Anzahl der Stockwerke:
7
Keller ja/nein:
Ja
Anzahl der beheizten Stockwerke:
1
Bruttogeschossfläche [m²]:
0,0
NGF Berechnungsmethode:
Außen:
Rendered
Innen:
Plastered (on hard)
Dach:
flat + single pitched roof
RENOVIERUNGS-PROZESS
Architektur
BESCHREIBUNG
Erhaltungszustand
DENKMALWERT
Ziel der Sanierung
Center za upravljanje z dediščino živega srebra Idrija
Bazoviška ulica 2, Idrija, 5280 Idrija
Aleš Hafner, univ.dipl.inž.arh. - Gea Consult
Mestni trg 5, 4220 Škofja Loka
Institute for the protection of cultural heritage of Slovenia
Delpinova 16, 5000 Nova Gorica
Ministry of Culture
Maistrova ulica 10, 1000 Ljubljana
SANIERUNGS-LÖSUNGEN
Außenwände
Concrete frame structure filled with bricks and windows
Concrete frame structure with masonry walls in between. All walls, except in the basement, are additionally thermally insulated with EPS panels on the inside of the building, and a cement spray performed over them.
300 mm
300mm
80 mm
15 mm
Fenster
Alu windows
The window openings remained the same, and the windows were replaced with ALU windows with double-layer thermopane glazing.
Neuer Fenstertyp | industrial thermopan alu window |
Verglasungsart des neuen Fensters | Double |
Verschattung des neuen Fensters | NA |
Weitere Maßnahmen
DACH
SONSTIGES
The roof is made of reinforced concrete beams, to which a wooden substructure is attached. The asbestos roofing has been replaced with a new suitable corrugated roofing. The roof is thermally insulated with soft mineral wool 25 cm thick, and the inside is lined with OSB panels, which are treated with cement spray over galvanized welded metal mesh.
0 mm
10 mm
250 mm
15 mm
15 mm
In some parts of the industrial plant there were additional modules (toilet, seminar room, elevator) established. They are heated and therefore also isolated as separate modules in the building.
In addition to the visitor centre all other parts of the building are kept very close to the initial state to serve the demonstration of the process. Areas where visitors stop (presentation elements, toilets) are separated from the other non heated areas.
HVAC
HEIZUNG
KLIMATISIERUNG
BRAUCHWARMWASSER
A boiler on pellets was constructed to heat the visitor centre. The radiating floor heating is in use in the visitor centre and radiators in other areas.
Heizungssystem nach Sanierung | |
---|---|
Art der Heizung | Boiler |
Brennstoff | Biomass |
Wärmeverteilung | Radiating floor |
Nennleistung | 150 kW |
New cooling system | |
---|---|
Type | air conditioner |
Distribuition system | Air |
Nominal power | kW |
Electric power | kW |
Combined with heating system.
Brauchwarmwasserbereitung nach Sanierung | |
---|---|
Typ | with heating system |
Brauchwasserspeicher | Ja |
Wärmerückgewinnung aus Brauchwasser | Nein |
ERNEUERBARE ENERGIE
Biomasse
Boiler on pellets is used to generate heat for heating and hot domestic water.
Biomass System | |
---|---|
Type | Pellet |
Storage size | |
Origin of biomass | |
Overall yearly production | kWh |
Energieeffizienz
Freiwillige Zertifikate Nein
Primärenergie
Berechnungsmethode NA
Kosten
2.300.000 eur
Nein